Laminated Glass Repair & Replacement in Chicago
Cracked, delaminating, or shattered laminated glass — measured, fabricated, and replaced by the same Chicago contractor that boards up the opening the night it breaks.
- Free field measure & written quote
- Phone answered 24/7
- Our own glaziers, no subs
What this work involves.
Laminated glass is two or more lites of glass permanently bonded to a plastic interlayer — usually PVB, sometimes a stiffer SentryGlas-type ionoplast where the glass is doing structural work. When it breaks, the interlayer keeps the fragments stuck to the sheet instead of dropping them. That's the whole point of it: the opening stays covered, nothing rains down on a sidewalk or a lobby floor, and the building stays closed to weather until the replacement lite shows up.
That same property is what makes people call us confused. A laminated lite that's been hit often looks survivable — it's still standing, still holding the opening, still spider-webbed in place. It is not repairable. Once the glass layer is cracked and the bond around the break has been disturbed, the assembly's strength and its weather seal are both gone, and the only real fix is a new lite. What we can do is buy you time, safely, which is where the board-up and temporary glazing side of our work comes in.
Chicago Glass Company of Illinois handles laminated work end to end — co-owners Brian Lowe and Sean Holas, our own glaziers, our own Melrose Park shop. We fabricate in house, we're a Kawneer and Oldcastle dealer for the framing side, and we buy glass through Vitro, so a laminated make-up gets specified, cut, and set by one company instead of three pointing at each other.


Where laminated glass is required — and where it's just the smarter choice
Some of it is code. Overhead and sloped glazing — skylights, canopies, glass walkways, anything installed above people — generally has to be laminated or have a laminated inboard lite, because a tempered lite that lets go overhead drops its pieces. Glass railings and guards in most commercial applications are the same story: laminated (often tempered-laminated) so a broken infill panel keeps standing until it's swapped.
The rest is judgment. Storefronts on hard-hit corridors get laminated because it survives a smash-and-grab attempt as a delay barrier. Ground-floor and vestibule glazing gets laminated for the same reason. Anywhere sound is a problem — a bar next to a bedroom wall, an office over a rail line — laminated with an acoustic interlayer does more than a thicker monolithic lite. And laminated blocks essentially all UV, which is why retail with merchandise in the window and museums and galleries specify it.
- Overhead, sloped, and skylight glazing
- Glass railings, guards, and stair infill
- Storefront and vestibule glazing on exposed corridors
- Security and forced-entry glazing build-ups
- Impact-adjacent applications where fragment retention is required
- Acoustic glazing near rail, highway, and nightlife noise
How we decide repair versus full replacement
Cracked or impacted laminated glass gets replaced. There's no resin injection or polish that restores a laminated lite's structural integrity or its seal, and anyone telling you otherwise is selling cosmetics on a safety component.
Delamination is the case worth a look. When you see cloudiness, bubbling, or a creeping haze at the edges, the interlayer bond is failing — usually from long-term water intrusion at a bad edge seal, or from years of a wet glazing pocket that never drained. If it's caught early and confined to one lite, that lite gets replaced and we fix the cause: reseal the pocket, correct the weeps, sometimes re-detail the frame so it stops happening to the next piece of glass.
Frame damage changes the answer again. If the impact bent the aluminum, cracked a corner, or tore out an anchor, replacing just the glass puts a new lite into a compromised opening. We survey the frame at the same visit, and because we bend and fabricate aluminum in our own shop, a bent Kawneer or Oldcastle member is something we can actually replace rather than work around.
Insulated units with a laminated lite
Plenty of Chicago commercial glazing is an insulated glass unit with one laminated lite — laminated outboard for impact and security, or laminated inboard for overhead and fall-protection applications. Those units are made to order: two lites, a spacer, a sealed cavity, and often a low-e coating on a specific surface.
That means there's no such thing as replacing the broken half. The whole unit is fabricated new, matched to the original thickness, coating, and interlayer so it looks identical to the lites next to it. We take the make-up off the existing unit's spacer stamp and edge deletion where it's legible, and off field measurement and glass thickness where it isn't. Getting the coating surface right matters — a low-e specified on the wrong surface reads as a visibly different pane from the sidewalk.
Security laminate upgrades when you're already replacing glass
The cheapest time to upgrade is while the opening is already open. If a storefront has been hit once, the replacement is the moment to move from annealed or tempered to a laminated security make-up — thicker glass, a heavier interlayer, and a proper glazing bite so the lite can't simply be pushed out of the frame after it's broken.
Where the budget or the schedule won't carry new glass, applied security film on existing glazing buys delay and fragment retention for far less. It is not bullet-resistant and we won't sell it as such. If the actual threat is a round rather than a crowbar, that's a UL 752 rated assembly and a different conversation.
The board-up bridge until the glass arrives
Laminated lites are made to order, and depending on thickness, interlayer, and whether it's an insulated unit, that's typically days rather than hours. 708-800-7120 is answered 24 hours a day for exactly that gap. We clean up, cut and fasten a board-up or set temporary glazing so the building is secure and dry, photograph the damage for your insurer, and then quote the permanent laminated replacement with a real lead time.
Broken laminated glass right now?
708-800-7120 is answered 24/7. We secure the opening tonight and quote the permanent lite.
- Board-up or temporary glazing the same night
- Damage photographed for your insurer
- Permanent laminated replacement quoted with a real lead time
Free quote. No obligation. Answered 24/7.
How a laminated glass replacement runs
1. Secure the opening
Same-day or same-night board-up or temporary glazing, glass cleaned up, damage photographed for the insurance file.
2. Field measure and read the make-up
Daylight opening, glass thickness, interlayer type, coating surface, and frame condition — so the new lite matches the ones beside it.
3. Fabricate
Laminated lites and insulated units with laminated lites ordered or fabricated to the written make-up, framing prep handled in our Melrose Park shop.
4. Set, seal, and close out
Our glaziers set the lite, correct the glazing pocket and weeps if that's what caused the failure, seal, clean, and hand over product data for the record.
Laminated make-ups we work with
Interlayer and build-up get chosen for what the glass has to do — hold fragments overhead, resist an attack, quiet a room, or all three.
- Standard PVB laminated lites, clear and tinted
- Structural ionoplast interlayers for railings and guards
- Tempered-laminated build-ups for guards and overhead glazing
- Insulated glass units with a laminated outboard or inboard lite
- Low-e coated laminated units matched to existing glazing
- Acoustic interlayers for noise-exposed openings
- Security and forced-entry laminated build-ups
- Applied security window film for retrofits and phasing
Where we do laminated glass work
Storefronts and vestibules across the city's retail corridors, overhead canopy and skylight glazing in the Loop and River North, stair and balcony railings in high-rise residential, and school, bank, and dispensary security glazing in the city and the collar counties.
Our shop is in Melrose Park and our showroom is in Elk Grove Village, so we're inside the city in twenty-five minutes and anywhere in the collar counties not much after that.
- The Loop & River North
- West Loop / Fulton Market
- North Side & Lakeview
- South Side & Southwest Side
- Oak Park & Berwyn
- Evanston & the North Shore
- O'Hare & Rosemont corridor
- Oak Brook & DuPage
Keep reading.
Tempered Glass Chicago
When tempered is the right safety glass instead.
ViewStorefront Glass Contractor
Full storefront and aluminum entrance work.
ViewBulletproof & Security Glazing
UL 752 rated assemblies and teller lines.
View24/7 Emergency Board-Up
Same-night response after a break.
ViewInsulated Glass Replacement
Sealed units, including laminated make-ups.
ViewSend us the opening — we'll match the make-up
Call 708-800-7120 or email service@chicagoglasscompany.com with the location, glass size, and a photo of the break. We'll come back with a laminated make-up, a lead time, and a fixed price — and we'll board it up tonight if it's open.
Free field measure & written quote · No obligation · Phone answered 24/7
Laminated glass questions we get
Straight answers before you spend money on the wrong fix.