    Insulated glass units (IGUs) don't fail all at once. They degrade gradually — and in Chicago's climate, where temperatures swing 100+ degrees between January and July, they take a beating. Here are the five clearest signs your commercial IGU needs to be replaced.

    1. Fogging or Condensation Between the Panes

    This is the most obvious sign of IGU failure. When you see fog, haze, or condensation that doesn't wipe off inside the glass cavity, the hermetic seal has failed. Moist air has entered the sealed unit, and the desiccant (the material in the spacer bar that absorbs moisture) is exhausted.

    A failed seal doesn't fix itself. Once moisture is in, the insulating gas (typically argon or air) is gone, thermal performance drops significantly, and the fogging gets worse. The unit needs to be replaced.

    2. Visible Condensation on the Interior Glass Surface in Winter

    This one gets confused with seal failure, but it's different. If condensation forms on the room-side surface of the glass during cold weather, the problem might not be a failed IGU — it could be insufficient interior temperature, high indoor humidity, or a glass spec that's too cold for your application.

    However, if it happens consistently on certain units and not others, those units may have lower thermal performance due to age or a partial seal failure. Worth having assessed.

    3. Drafts Near the Glass

    If occupants complain about cold air near windows that isn't coming from gaps in the frame or perimeter sealant, the glass itself may be under-performing thermally. Older clear double-pane units with no low-e coating have center-of-glass U-factors around 0.48–0.55. Modern low-e units run 0.20–0.30. The difference is felt.

    Replacing older clear IGUs with low-e units — Cardinal LoE-272 or LoE-366 are common specs — typically pays back in energy savings within a few years on a well-glazed building.

    4. Cracked or Broken Panes

    Obvious, but worth stating: any cracked or broken IGU pane needs immediate replacement. A single broken pane compromises the entire unit — the seal is gone, thermal performance is zero, and there's a safety risk depending on the glass type.

    In Chicago, thermal stress cracking (cracks that originate at the edge and run inward at roughly 90 degrees) happens in glass that's shadowed by interior blinds or shades, particularly on south and west exposures. Heat-strengthened or tempered glass is more resistant.

    5. Age — 15–20 Years on the Original Units

    IGU seals have a service life. In Chicago's climate, well-made units with quality spacers (warm-edge or stainless) typically last 15–25 years. Aluminum spacer units (the old standard) tend to fail earlier because aluminum conducts cold to the seal perimeter, accelerating degradation.

    If your building was glazed in the early 2000s or before and you haven't replaced units, it's worth having a glazier assess the condition. Proactive replacement during planned downtime is significantly cheaper than emergency replacement after a unit fails.

    Getting Units Replaced in Chicago

    We replace IGUs in existing aluminum storefront frames, curtain wall systems, and residential applications throughout Chicago and the collar counties. We stock Cardinal glass and can match most existing specs (size, thickness, spacer color, low-e coating).