FireLite NT · 20-minute reference
Technical Glass Products (TGP) · R230302 · © 2023 · checked November 20, 2026
Pages 1–3; 20-to-60-minute rows on page 2
- Material
- Glass ceramic with surface-applied fire-rated film
- Overall thickness
- 3/16 in. (5 mm), for this named product only
- Non-temperature-rise doors
- Maximum exposed area 3,204 sq. in.; maximum exposed width 36 in. and height 89 in.
- Temperature-rise doors
- Maximum exposed area 100 sq. in.; maximum exposed width 12 in. and height 33 in.
- Other than doors
- Maximum exposed area 3,325 sq. in.; maximum exposed width and height 95 in.
Limits and compatibility
- These are TGP's published limits for FireLite NT, not a glass size or product selected for your job. Area, width and height limits apply together; the frame manufacturer must confirm maximum tested glass sizes and required stop height.
- FireLite NT is not a barrier to radiant heat and does not meet ASTM E119 or UL 263. A time rating alone does not establish suitability for a fire-resistive wall.
- Page 3 calls for appropriate fire-rated framing and an approved glazing compound: closed-cell PVC tape or DAP 33 putty. This is product-specific guidance, not permission to substitute materials in another listed system.