Skip to main content Book a site visit · we confirm who and when
    Fire-rated glazing · quote only

    90-Minute Fire-Rated Glass

    Ninety minutes, or one and a half hours, quoted as a complete listed assembly: the glass, the frame, the glazing tape and the anchorage together.

    What it is

    A fire rating is a time. A 90-minute (1½-hour) rating means the assembly it belongs to was tested and listed for 90 minutes. The number applies to that listed assembly as a whole, not to glass installed in any frame.

    We quote it that way. The glass, the frame, the glazing tape and the anchorage are matched to the same listed system. We work from the listing for your assembly.

    We also quote 20-minute fire-rated glass, and our fire-rated work runs up to 3-hour full wall assemblies. See our fire-rated glazing page for the whole range.

    Manufacturer documents

    Reference specifications

    These published examples explain what to check. CGC has not selected or confirmed these manufacturers or products for your order. They are not a project submittal, a CGC certification or proof of the system shown in our project photo.

    Send the drawings, required rating and existing frame label. We’ll confirm the actual glass, frame, glazing materials and applicable listing in the written quote. The authority having jurisdiction reviews the assembly for your project.

    FireLite NT · 90-minute reference

    Technical Glass Products (TGP) · R230302 · © 2023 · checked November 20, 2026

    Pages 1–3; 90-minute rows on page 2, tape requirement on page 3

    Manufacturer PDF
    Material
    Glass ceramic with surface-applied fire-rated film
    Overall thickness
    3/16 in. (5 mm), for this named product only
    Non-temperature-rise doors
    Maximum exposed area 2,034 sq. in.; maximum exposed width 36 in. and height 56-1/2 in.
    Temperature-rise doors
    Maximum exposed area 100 sq. in.; maximum exposed width 12 in. and height 33 in.
    Other than doors
    Maximum exposed area 2,627 sq. in.; maximum exposed width and height 56-1/2 in.
    Tape requirement
    For 90-minute ratings exceeding 1,393 sq. in., TGP specifies fire-rated glazing tape supplied by TGP.

    Limits and compatibility

    • These are TGP's published limits for FireLite NT, not a glass size or product selected for your job. Area, width and height limits apply together; the frame manufacturer must confirm maximum tested glass sizes and required stop height.
    • FireLite NT is fire-protective, not a barrier to radiant heat: it does not meet ASTM E119 or UL 263. A 90-minute rating does not automatically make glass fire-resistive or suitable for a rated wall.
    • The 1,393-sq.-in. tape threshold applies to this manufacturer's FireLite NT instructions. It is not a universal threshold for 90-minute glass or permission to substitute tape.

    Where we use it

    • Openings where the project drawings or the label on the existing frame call for a 90-minute rating

    From the field

    One listing, four parts

    The glass, the frame, the glazing tape and the anchorage have to match the same listed system. Mix parts from different systems and the assembly's rating no longer applies.

    Read the rating off the drawings

    The code and the project drawings set the rating, and the authority having jurisdiction signs off. Send the rating from the drawings or the existing frame label. If you are not sure, call us before you order.

    Check the listing limits

    Each listed system has its own limits on glass size, framing and installation. We work from the listing for your assembly, not from a rule of thumb.

    Existing frames

    If the glass is going into an existing frame, send photos and sizes. We will tell you what else we need before we quote.

    Written estimates

    We quote in writing and keep materials and labor separate. Timing depends on scope and availability and is confirmed in the written quote.

    2-hour fire-rated glass wall at Wrigley Field in Chicago
    CGC's 2-hour fire-rated glass wall at Wrigley Field. This project shows a different rating from the glass on this page.

    Project request

    Request this system for your project

    Send the opening, location, and any drawings you have. We’ll review the system and call you back.

    Written estimate
    Tell us about the job.

    For emergencies, call 708-800-7120. Privacy Policy

    Frequently Asked Questions

    What does 90-minute fire-rated glass mean?+

    It means the glass is part of an assembly tested and listed for 90 minutes, or 1½ hours. The rating belongs to the listed assembly as a whole, not to glass installed in any frame.

    Who decides whether I need 90-minute glass?+

    The building code and the project drawings set the rating, and the authority having jurisdiction signs off. If the drawings do not show it, call 708-800-7120 and tell us about the opening.

    Can 90-minute glass go into any frame?+

    No. A listing covers a specific combination of glass, frame, glazing tape and anchorage. We match the glass to the frame before we quote.

    How is it priced?+

    Quoted in writing, with materials and labor separated. Timing depends on scope and availability and is confirmed in the quote.

    Send us the opening and the project requirements.

    We quote in writing and keep materials and labor separate. Timing depends on scope and availability and is confirmed in the written quote.

    WhatsApp photos