FireLite NT · 90-minute reference
Technical Glass Products (TGP) · R230302 · © 2023 · checked November 20, 2026
Pages 1–3; 90-minute rows on page 2, tape requirement on page 3
- Material
- Glass ceramic with surface-applied fire-rated film
- Overall thickness
- 3/16 in. (5 mm), for this named product only
- Non-temperature-rise doors
- Maximum exposed area 2,034 sq. in.; maximum exposed width 36 in. and height 56-1/2 in.
- Temperature-rise doors
- Maximum exposed area 100 sq. in.; maximum exposed width 12 in. and height 33 in.
- Other than doors
- Maximum exposed area 2,627 sq. in.; maximum exposed width and height 56-1/2 in.
- Tape requirement
- For 90-minute ratings exceeding 1,393 sq. in., TGP specifies fire-rated glazing tape supplied by TGP.
Limits and compatibility
- These are TGP's published limits for FireLite NT, not a glass size or product selected for your job. Area, width and height limits apply together; the frame manufacturer must confirm maximum tested glass sizes and required stop height.
- FireLite NT is fire-protective, not a barrier to radiant heat: it does not meet ASTM E119 or UL 263. A 90-minute rating does not automatically make glass fire-resistive or suitable for a rated wall.
- The 1,393-sq.-in. tape threshold applies to this manufacturer's FireLite NT instructions. It is not a universal threshold for 90-minute glass or permission to substitute tape.